Endress+Hauser Proline Prosonic Flow 93T ultrasonic flowmeter
The economical flowmeter for easy data transfer via USB stick without additional software.
-
- Max. measurement error
- +/-2.0 %
- Max. measurement error
-
- Measuring range
- 0….452’389 m3/h
- Measuring range
-
- Medium temperature range
- DN 15…65 : -40…+150°C (-40…+302°F)
- DN 50…300 : -40…+170°C (-40…+338°F)
- DN 100…4000 : -40…+80°C (-40…+176°F)
- Medium temperature range
Field of application
The portable ultrasonic flowmeter Prosonic Flow 93T is designed for temporary monitoring and test measurements with clamp on sensors. It is operated independently of the mains power using a battery. The Prosonic Flow 93T is ideal for conducting verification measurements at existing flow metering points.
The sensors are perfectly suited for the non-contact measurement of pure or slightly contaminated liquids, regardless of the pressure or electrical conductivity.
-
Ideal solution for temporary use everywhere precise measurement or verification is required
-
Can be used with all metal and plastic pipes lined or unlined and with composite pipes
-
Suitable for pipe diameters from DN 15 to 4000 (½ to 160″)
-
Suitable for fluid temperatures ranging from –40 to +170 °C (–40 to +338 °F)
Benefits
-
Automatic frequency scan for maximum measuring performance
-
Quick and secure installation – specially designed mounting kits
-
No additional leakage paths – external measurement from outside the pipe
-
Process transparency – diagnostic capability
-
Temporary monitoring of measuring points – portable flowmeter with rechargeable battery and current output
-
Verification of other flow devices – integrated data logger and current input
-
Automatic recovery of data